

Summary of Testing Protocol
A full description of the cigarette and multi-purpose lighter testing protocol summarized below and additional manufacturer requirements can be found in 16 CFR 1210 and 16 CFR 1212.Child Testing Protocol
Each test is made up of 1 to 2 panels of 100 children between the ages of 42 and 51 months.Panels are divided into 3 groups according to age:
30% between the ages of 42 and 44 months
40% between the ages of 45 and 48 months
30% between the ages of 49 and 51 months
Approximately 2/3 of the children in each of the age groups must be boys.
All children must be healthy with no disabilities or injuries that could potentially affect their ability to test the lighter.
Children may not participate in both cigarette and multi-purpose lighter testing or package testing in the same day.
Children are tested in pairs in a room that is well-lit, free of distractions, and is familiar to them, or in a central location in which they feel comfortable, by a tester who administers the test to no more than 20% of the sample.
To begin, the tester operates a surrogate lighter in the presence of the children who are to be tested without letting them see how it was operated so they will know what sound or visual signal the lighter makes when operated correctly. Each child is then given a surrogate lighter and asked to try to make the same sound or visual signal. The children are allotted 5 minutes to try to operate the lighter correctly. The tester uses a stopwatch to keep track of the time.
If a child is able to operate the lighter successfully, the test is counted as a failure and he or she is not tested further. If the second child has not been able to operate the lighter successfully at this point, they are allowed to continue for the remainder of the allotted test period.
If a child (or children) is unable to correctly operate the lighter within the allotted 5 minutes, the tester demonstrates how to do so. The child is then given an additional 5 minutes to try again. If the child is able to operate the lighter within this period, this is also counted as a failure.Pass/Fail Criteria:
A test is determined a failure if the child is able to produce the sound or visual signal by correctly operating the surrogate lighter.
For a lighter to pass in the first panel of 100 children, 10 or fewer must have been able to operate the surrogate lighter. Conversely, if 19 or more children operate the surrogate lighter successfully, the lighter fails. In both cases, no further testing is necessary.
In the first panel of 100 children, if 11-18 operate the surrogate lighter successfully, a second panel of 100 children must be tested. In the event that the second panel is tested, the lighter fails if 31 or more of the 200 children tested are able to operate the surrogate lighter successfully.

NEED A PRODUCT TEST REPORT?
Contact today PTS Testing Lab, Get best testing solution! Secure the optimal test lab strategy at an exceptionally competitive rate!
Contact US:King chan +86 136023 86325 or Miss Yang +86 188 2584 1124 E-mail:pts-test@foxmail.com